dc.rights.license | http://creativecommons.org/licenses/by-nc-sa/3.0/ve/ | |
dc.contributor.author | González Rivas, Juan Pablo | |
dc.date.accessioned | 2016-11-30T18:52:43Z | |
dc.date.available | 2016-11-30T18:52:43Z | |
dc.date.issued | 2016-10 | |
dc.identifier.issn | 1690-3110 | |
dc.identifier.uri | http://www.saber.ula.ve/handle/123456789/42687 | |
dc.description.abstract | La medición de la presión arterial (PA) en la consulta de forma correcta permite una adecuada estratificación del riesgo de los pacientes, sin embargo, su técnica puede estar sometida a errores frecuentes que deben ser evitados. Los esfigmomanómetros de mercurio han sido el estándar de oro en la toma de PA, sin embargo, no están actualmente recomendados debido al riesgo de toxicidad; sus alternativas, el esfigmomanómetro aneroide, requiere calibración periódica para evitar mediciones erróneas, y los equipos oscilométricos deben ser validados
y adecuadamente seleccionados para su función. Mediciones complementarias a la realizada en la consulta, como el monitoreo ambulatorio de PA y la medición en casa, suplementan algunas debilidades de la medición en la oficina. El objetivo de la presente revisión fue evaluar cada uno de los aspectos de la técnica para medir la PA en la consulta. | es_VE |
dc.language.iso | es | es_VE |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Presión arterial | es_VE |
dc.subject | Medición | es_VE |
dc.subject | Riesgo | es_VE |
dc.subject | Dispositivos | es_VE |
dc.title | Optimizando la Medición de la Presión Arterial en la Consulta | es_VE |
dc.title.alternative | Optimizing the office Blood Pressure Measurement | es_VE |
dc.type | info:eu-repo/semantics/article | |
dc.description.abstract1 | A proper office blood pressure (BP) measurement allows a right risk stratification of the patients, however, its technique can have frequently errors that must be avoided. Mercury phygmomanometers has been the gold standard on BP measurement, however, due to its toxicity risk are not currently recommended; other alternatives, like the
aneroid sphygmomanometer require routinely calibration to avoid mistakes, and oscillometric devices require be
validated and properly selected. Complementary techniques of office BP measurement, like the ambulatory BP
measurement and home measurement, supplement some weaknesses related to the office BP measurement. The objective of this review was to evaluate each aspect on the technique to perform the office BP measurement. | es_VE |
dc.description.colacion | 179-186 | es_VE |
dc.identifier.depositolegal | 200902ME4351 | |
dc.publisher.pais | Venezuela | es_VE |
dc.subject.dependencia | Sociedad Venezolana de Endocrinología y Metabolismo | es_VE |
dc.subject.facultad | Facultad de Medicina | es_VE |
dc.subject.institucion | Universidad de Los Andes | es_VE |
dc.subject.keywords | Blood pressure | es_VE |
dc.subject.keywords | Measurement | es_VE |
dc.subject.keywords | Risk | es_VE |
dc.subject.keywords | Devices | es_VE |
dc.subject.seccion | Revista Venezolana de Endocrinología y Metabolismo: Editorial | es_VE |
dc.subject.thematiccategory | Medicina y Salud | es_VE |
dc.subject.tipo | Revistas | es_VE |
dc.type.media | Texto | es_VE |