| dc.rights.license | http://creativecommons.org/licenses/by-nc-sa/3.0/ve/ | |
| dc.contributor.author | González Fernández, Rumualdo | |
| dc.contributor.author | Soto Belloso, Eleazar | |
| dc.contributor.author | Velarde, Juan Carlos | |
| dc.contributor.author | De Ondiz, Aitor | |
| dc.date.accessioned | 2009-02-19T13:08:53Z | |
| dc.date.available | 2009-02-19T13:08:53Z | |
| dc.date.issued | 2009-02-19T13:08:53Z | |
| dc.identifier.issn | 0798-2259 | |
| dc.identifier.uri | http://www.saber.ula.ve/handle/123456789/26871 | |
| dc.description.abstract | La eficiencia de recolección de embriones bovinos de dos filtros, EmCon y Rugofer, fue evaluada en 32 vacas donadoras mestizas cebú superovuladas con FSH-P. Los filtros Rugofer y Emcon fueron usados en la recolección no-quirúrgica de 17 y 15 vacas respectivamente. Un total de 126 y 124 embriones fueron recolectados con cada filtro. De acuerdo al número de cuerpos lácteos, la tasa de recolección fue de 82.3% y 93.9%, y de 7.1 y 8.2 embriones por vaca para los filtros Rugofer y EmCon respectivamente (P>0.05). De estos resultados, podemos concluir que ambos tipos de filtros tuvieron la misma eficiencia de separación de embriones. El filtro regular tuvo la ventaja de ser reusable, de bajo costo y resistente a la esterilización (120º C/1h). | es_VE |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Recolección | es_VE |
| dc.subject | Embriones | es_VE |
| dc.subject | Filtro | es_VE |
| dc.subject | Bovino | es_VE |
| dc.title | Comparación de dos modelos de filtros de separación de embriones bovinos | es_VE |
| dc.title.alternative | Comparisson of two filters models for separation of bovine embryos | es_VE |
| dc.type | info:eu-repo/semantics/article | |
| dc.description.abstract1 | The bovine embryo collection of two filters, Emcon and Rugofer was evaluated in 32 crossbred cebu donor cows superovulated with FSH-P. The Rugofer and Emcon filters were used for no-surgical in 17 and 15 cows respectively. A total of 126 and 124 embryos were recovered with each filter. According to the number of corpus luteum the recollection rate was 82.3% and 93.9% being 7.1 and 8.2 embryos for the Rugofer and Emcon filters respectively (P>0.050.05). From these results we concluded that both type of filters had the same efficiency for embryo separation. The Rugofer filter had the advantage of being reusable, a lower cost and sterilization resistance (120º C/1h). | es_VE |
| dc.description.colacion | 37 - 38 | es_VE |
| dc.description.frecuencia | Cuatrimestral | |
| dc.identifier.depositolegal | 199102ZU46 | |
| dc.subject.Mots-cles | Filter | es_VE |
| dc.subject.Mots-cles | Bovine | es_VE |
| dc.subject.institucion | Universidad del Zulia (LUZ) | es_VE |
| dc.subject.institucion | Universidad de Los Andes (ULA) | es_VE |
| dc.subject.keywords | Collection | es_VE |
| dc.subject.keywords | Embryos | es_VE |
| dc.subject.publicacionelectronica | Revista Científica | |
| dc.subject.tipo | Revistas | es_VE |
| dc.type.media | Texto | es_VE |