Afficher la notice abrégée

dc.rights.licensehttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/
dc.contributor.authorGonzález Fernández, Rumualdo
dc.contributor.authorSoto Belloso, Eleazar
dc.contributor.authorVelarde, Juan Carlos
dc.contributor.authorDe Ondiz, Aitor
dc.date.accessioned2009-02-19T13:08:53Z
dc.date.available2009-02-19T13:08:53Z
dc.date.issued2009-02-19T13:08:53Z
dc.identifier.issn0798-2259
dc.identifier.urihttp://www.saber.ula.ve/handle/123456789/26871
dc.description.abstractLa eficiencia de recolección de embriones bovinos de dos filtros, EmCon y Rugofer, fue evaluada en 32 vacas donadoras mestizas cebú superovuladas con FSH-P. Los filtros Rugofer y Emcon fueron usados en la recolección no-quirúrgica de 17 y 15 vacas respectivamente. Un total de 126 y 124 embriones fueron recolectados con cada filtro. De acuerdo al número de cuerpos lácteos, la tasa de recolección fue de 82.3% y 93.9%, y de 7.1 y 8.2 embriones por vaca para los filtros Rugofer y EmCon respectivamente (P>0.05). De estos resultados, podemos concluir que ambos tipos de filtros tuvieron la misma eficiencia de separación de embriones. El filtro regular tuvo la ventaja de ser reusable, de bajo costo y resistente a la esterilización (120º C/1h).es_VE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectRecolecciónes_VE
dc.subjectEmbrioneses_VE
dc.subjectFiltroes_VE
dc.subjectBovinoes_VE
dc.titleComparación de dos modelos de filtros de separación de embriones bovinoses_VE
dc.title.alternativeComparisson of two filters models for separation of bovine embryoses_VE
dc.typeinfo:eu-repo/semantics/article
dc.description.abstract1The bovine embryo collection of two filters, Emcon and Rugofer was evaluated in 32 crossbred cebu donor cows superovulated with FSH-P. The Rugofer and Emcon filters were used for no-surgical in 17 and 15 cows respectively. A total of 126 and 124 embryos were recovered with each filter. According to the number of corpus luteum the recollection rate was 82.3% and 93.9% being 7.1 and 8.2 embryos for the Rugofer and Emcon filters respectively (P>0.050.05). From these results we concluded that both type of filters had the same efficiency for embryo separation. The Rugofer filter had the advantage of being reusable, a lower cost and sterilization resistance (120º C/1h).es_VE
dc.description.colacion37 - 38es_VE
dc.description.frecuenciaCuatrimestral
dc.identifier.depositolegal199102ZU46
dc.subject.Mots-clesFilteres_VE
dc.subject.Mots-clesBovinees_VE
dc.subject.institucionUniversidad del Zulia (LUZ)es_VE
dc.subject.institucionUniversidad de Los Andes (ULA)es_VE
dc.subject.keywordsCollectiones_VE
dc.subject.keywordsEmbryoses_VE
dc.subject.publicacionelectronicaRevista Científica
dc.subject.tipoRevistases_VE
dc.type.mediaTextoes_VE


Fichier(s) constituant ce document

Thumbnail
Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée